Luup Variables. The "Variables" for a device tell you it's current state, such as if it's on or off, what temperature it has, and so on. Variables are given a name and a service ID, which is defined by the UPnP forum. You can use this service ID/variable name pair to get the state of a device in the Luup engine by using the function luup

5787

Login via PuTTY (linux) - note: right click seems to be paste Enter IP of Vera root your veras wifi password. To see logs cd /var/log/cmh tail -f LuaUPnP.log. Ctrl C to stop Expect logs not to be instant. Can filter logs with grep ocmmands tail -f LuaUPnP.log | grep "^04|^08" tail -f LuaUPnP.log | grep "Tonys"

local allow = true -- true runs scene during daytime, false runs it at night. local status = luup.variable_get ("urn:rts-services-com:serviceId:DayTime","Status",dID) return ( (status == "1") == allow) Other examples. Z-Wave and Virtual Switches. It involves a very short piece of LUA code - but don't worry, all the information is here. Full Device ID List. In the VERA UI go to the APPS tab; Click the Develop Apps tab; Then click 'Test LUUP code (LUA)' in the left-hand menu; Copy the LUA code (below) and paste it into the Code window; Click the blue 'GO' button to make the code run Now its time for the LUUP code, which need to be applied within this scene also: luup.call_delay ('scene_controller', 1) function scene_controller () local lastSceneID= luup.variable_get ("urn:micasaverde-com:serviceId:SceneController1", "LastSceneID", 135) if (lastSceneID== "11") then luup.call_action ("urn:micasaverde-com:serviceId:HomeAutomationGateway1","RunScene", { SceneNum="1" },0) elseif (lastSceneID== "12") then luup.call_action My home automation scripts.

  1. Luup code vera edge
  2. Bas mixture

I am eager to get started with Luup but all I read about is what it can do, not how to actually do it. Need someone to write a very basic LUA script that will execute on a Vera Edge receiver. Here's some info about Vera LUUP Scenes: [url removed, login to view] The logic is very basic. I will execute the scene every 15 minutes on a schedule. The scene runs the LUUP/LUA script code.

This is an essential tool for managing Vera logic. I use 10 of these to set various states and conditions. For example, I use a VSwitch to control whether or not the Vera wakes us up on a work day. (VSwitch ON for Workday Wake-up). I verify states through LUUP to determine whether or not to allow scenes to activate. read more.

Z-Wave and Virtual Switches. It involves a very short piece of LUA code - but don't worry, all the information is here. Full Device ID List.

Then use the "Luup event" button against the event in the triggers listing to create Lua code which will upload the event into Cosm using the current time as the 

Instead, you will start the debugging session in the IDE before running the code on your Vera. Copy the following code into a new Automation scene on the Vera under the Luup tab.

If you have remote sensors connected to your thermostat, they should also be accessible via this plugin. 14 Mar 2017 Reset kWh in Vera UI7 Print. Modified on: Tue, 14 Mar, This is the LUUP code that you need to reset kWh to 0: LUUP Code. local meterID =  actions directly in LUUP code.
Indiskt tunt bomullstyg perkal

Luup code vera edge

http://vera_lite_ip_address:3480/data_request?id=device&action=delete&device=666 Tested this last night a number of times and worked perfectly, thanks. Vera luup startup functions. GitHub Gist: instantly share code, notes, and snippets.

Ctrl C to stop Expect logs not to be instant. Can filter logs with grep ocmmands tail -f LuaUPnP.log | grep "^04|^08" tail -f LuaUPnP.log | grep "Tonys" Hello.
Universitet meritvärde

Luup code vera edge black death vodka systembolaget
ta personality types
motala bromma
resebyrå kalmar tågresor
hotell i vadstena sverige
higgspartikeln nobelpris

Need someone to write a very basic LUA script that will execute on a Vera Edge receiver. Here's some info about Vera LUUP Scenes: [url removed, login to view] The logic is very basic. I will execute the scene every 15 minutes on a schedule. The scene runs the LUUP/LUA script code. The code needs to do the following: - check if a website is

Thank you so much for your help. Replace at the beginning (vera_lite_ip_address) with that of the IP address of your vera controller and change the numbers at the end (666) to that of the appropriate device you're trying to delete and hit enter. http://vera_lite_ip_address:3480/data_request?id=device&action=delete&device=666 Tested this last night a number of times and worked perfectly, thanks.


Byta losenord
baby modelling sydney

2015-04-23 · The pages are to be found at "docs.mios.com" for the older Vera UI2 or at "docs2.mios.com" for the more recent Vera UI4. This last page can also be reached by clicking here. Also, the Mios homepage provides a basic setup guide for Vera here. Vera uses custom software that can be upgraded.

read more. Instead, you will start the debugging session in the IDE before running the code on your Vera. Copy the following code into a new Automation scene on the Vera under the Luup tab.

Vera Control. March 24 at 9:19 AM. According to this recent article by AnalyticsInsight.net, multi-radio 📶smart home hubs like the Ezlo Plus and Ezlo Secure are projected to …

Here is the vera config for the serial port. Serial Port configuration If you connected the USB/serial device and it's not displayed here, reload Luup.Reload Luup … Introduction.

3 = The code is programmed into the lock and will be removed by software later. 4 = The code is not programmed into the lock, but it will be programmed later by the software. 5 = The code is programmed into the lock which supports hardware-based scheduling and will enable/disable it automatically.